Packaged rooftop heat pump on a flat commercial roof in Boston, set on a curb adapter with its electrical disconnect beside it
SizedFrom a room-by-room load calculation at your town's design temperature
MeasuredDuct static pressure and airflow before and after
TestedNitrogen pressure test and deep vacuum before the charge
In writingEquipment, duct work, electrical and permits listed line by line

What a commercial heat pump job in Brighton looks like

The old gas rooftop units on their curbs before the lift, Brighton, near Brighton Center
The old gas rooftop units on their curbs before the lift
New packaged heat pump set on a flashed curb adapter, Brighton, near Brighton Center
New packaged heat pump set on a flashed curb adapter

The building and the problem

A single-story dental office near Brighton Center runs on two rooftop units from the mid-2000s, a 5-ton and a 4-ton, with gas heat and R-22 cooling. One heat exchanger is cracked, the cooling side needs refrigerant every summer, and the treatment rooms swing warm and cold while patients sit still.

What the load calculation changes

The load counts about 300 cubic feet a minute of outdoor air the office has to bring in. Even so, the building needs 8 tons, not 9: a 5-ton packaged heat pump for the treatment wing and a 3-ton unit for the front office, each with electric heat sized for Boston's 7°F design night.

Crane day

On Friday after the last patient, a licensed gas fitter caps both gas lines and the old refrigerant is recovered. On Saturday a boom truck in the rear lot lifts the old units off, curb adapters go onto the existing curbs and are flashed into the membrane, and the new units are set. No new roof openings.

Wiring, controls and startup

On Monday the 5-ton circuit goes from 60 to 80 amps on the building's 208-volt three-phase service. Thermostats follow office hours with a shallow night setback, and the strips lock out above 25°F except in defrost. Mass Save's commercial pre-approval, 8 tons at $2,000 a ton, is in hand before ordering.

Project facts
ServiceCommercial rooftop heat pumps
WhereBrighton, near Brighton Center
BuildingSingle-story dental office, about 3,000 sq ft
BeforeTwo gas-heat rooftop units, 9 tons
After5-ton and 3-ton packaged heat pumps
Price$61,800 before rebates
Time on siteThree working days, crane on a Saturday

Two rooftop units past 20 years old, gas for the heat, and a repair call every summer for the cooling. Clement Boston Heat Pumps handles commercial heat pump installation for buildings like that: small offices, shops and clinics, plus small apartment and condo buildings, across Boston and the towns around it.

We work on three kinds of system: packaged rooftop heat pumps, ducted split systems, and one system per apartment. Each job is priced from a site visit and a written estimate, because tonnage, roof access and the electrical service move the number more than the unit does.

Which commercial system fits your building?

The building usually decides. Rooftop units now means a packaged heat pump on the same curb. An air handler inside means a split system. Apartments get a system each.

Rooftop packaged heat pumps

A packaged unit holds the compressor, both coils, the fan and the controls in one cabinet. It sits on a roof curb over the supply and return ducts. Swapping a gas-fired rooftop unit for a heat pump keeps the ducts and the roof opening, and puts electric heat where the gas burner was.

Curbs differ from maker to maker, so most swaps need a curb adapter: a sheet metal transition that fits the new footprint to the old openings without a new hole in the roof.

Ducted split systems

An office or storefront with its air handler above the ceiling or in a closet gets a split system. The outdoor unit goes on the roof or at grade, a copper line set runs to the indoor air handler, and the existing ducts stay if they carry enough air.

Line length and the route through the building set much of the price.

One system per apartment

In a small apartment or condo building, each unit gets its own ducted heat pump on its own meter. Outdoor units go on the roof or in the rear yard, and every line set through a floor gets fire-rated sealing.

Our triple-decker guide covers the layouts, and the condo replacement guide covers working with an association.

What happens on the site visit

We look at the roof, the mechanical spaces and the electrical service, read the nameplates on what’s there, and work out the load. All of it goes into one written estimate.

  • The load. A commercial building has to bring in outdoor air for ventilation. In January that air arrives in single digits and has to be heated, so a clinic or a shop with a busy door needs more heat than its floor area suggests.
  • The roof or the ceiling. Curb size and condition, the membrane around each curb, the crane’s path, and whether a ceiling can open for an air handler and line set.
  • The electrical service. Voltage and phase (small commercial buildings often run 208-volt three-phase), the service size, and breaker room for units with electric heat. If the service is short, an upgrade goes on the estimate.
  • The controls. Occupied hours, who touches the thermostat, and whether gas heat stays as backup.

You get back the equipment and its heating capacity at the design temperature, the curb plan, the crane day, the electrical work, permits, the rebate path and our price.

Cold nights, fresh air and backup heat

A packaged heat pump loses capacity as it gets colder, just when the ventilation air is coldest. So every commercial unit we specify carries backup heat sized for the design night, and the controls decide when it runs.

Electric or gas backup

Most packaged heat pumps come with electric heat strips. Some buildings keep a gas section in a dual-fuel rooftop unit and let the heat pump carry milder weather. If gas stays, Mass Save’s commercial rebate asks for controls that run the heat pump first, down to a set switchover temperature.

Occupied hours

Offices set back at night. A heat pump recovering from a deep setback leans on backup heat, so we program a shallow setback and an earlier morning start instead. The heat pump thermostat guide explains the same logic for homes, and the aux heat guide covers what the strips cost to run.

Crane day, roof work and permits

Rooftop work runs around one fixed day: the crane. Everything else is arranged so the old units come down and the new ones go up in a single lift window.

  1. Permits first. Electrical, sheet metal and, where the roof or structure changes, building. Some building departments ask for engineered drawings on commercial work; those are lined up before equipment is ordered.
  2. The lift plan. Crane size and reach from the parking lot or the street. A crane in a city street needs the city’s approval to occupy it, so the day is set early.
  3. The day before. Units disconnected, gas lines capped by a licensed gas fitter, refrigerant recovered.
  4. Lift day. Old units off, curb adapters set and flashed into the roof, new units on.
  5. Startup. Wiring, controls, a startup check on each unit and the occupied schedule set.

A newer gas rooftop unit with years left doesn’t have to come off. When one is worth keeping, the estimate says so.

Mass Save’s commercial heat pump rebate

Mass Save pays $2,000 per ton for qualifying commercial air-source heat pumps on projects up to 35 tons, and reviews larger projects one at a time. Every commercial project needs pre-approval before installation.

Item What it means for you
Who qualifies Buildings on a commercial account with a Mass Save electric or gas sponsor
Equipment Units on Mass Save’s commercial qualified product list
If gas or oil stays Integrated or certified parallel controls, so the heat pump runs first
Timing A commitment letter before installation, valid for four months

Apartments on residential electric accounts generally go through Mass Save’s residential programs; our Mass Save rebate guide covers those, and we confirm which applies before pricing. Buildings in light plant towns such as Peabody or Braintree follow that utility’s programs on the electric side.

Boston’s building emissions rules

Boston’s BERDO rules cover residential buildings with 15 or more units and non-residential buildings of 20,000 square feet or more. A small office or a six-unit building sits below those lines, but an owner who also holds a covered building can plan the two together.

How we price commercial work

We price each building from the site visit, not from a per-ton chart. The written estimate breaks out every piece that moves the number.

  • Tonnage from the load calculation, including the ventilation air
  • Crane size, reach and street access, and whether the lift happens outside business hours
  • Curb adapters, roof flashing and any roof repair around the curbs
  • Electrical: voltage, phase, breaker room and new disconnects
  • Controls, and whether gas heat stays as backup
  • Permits, any drawings the building department asks for, and the pre-approval timing

For house-scale work, our cost guide lists our residential ranges. A commercial building gets its own number, and the rebate comes off once the commitment letter is in hand.

What's included

Three ways we put heat pumps into small commercial buildings

Rooftop packaged heat pumpDucted split systemOne system per unit
Typical buildingSingle-story office, shop or clinic with rooftop units nowOffice or storefront with an air handler above the ceiling or in a closetA small apartment or condo building
Where the equipment goesEverything in one cabinet on the roof curbOutdoor unit on the roof or at grade, air handler insideAn outdoor unit and air handler for each apartment
Install dayA crane lifts the units on and offA line set runs between the two halvesLine sets and sealed penetrations through each floor
Who pays the electric billThe businessThe businessEach household, on its own meter
What moves the priceTonnage, curb fit, crane accessLine length, ceiling access, duct changesNumber of units, roof or yard space, fire-rated sealing

Related resources

How a job runs

First call

You tell us what heats and cools the house now, which rooms aren't working, and roughly where the house is.

Home visit

We measure the house for a load calculation, test the ducts, check the panel and look for an outdoor spot.

Written estimate

Equipment, duct changes, electrical, permits and the rebate path, line by line, with our price.

Install

Permits first, then the work: usually two to five working days on site.

Commissioning

Pressure test, vacuum, charge by weight, airflow and controls set before we call it done.

Rooftop units near the end?

Send nameplate photos and the building's size. We'll visit, measure and send a written estimate with our price.

Commercial heat pumps: questions

Can a packaged heat pump go on our existing rooftop curb?

In most cases, yes, with a curb adapter. The adapter is a sheet metal transition that matches the new unit's footprint to the old supply and return openings, so the roof isn't cut again. We measure the curb and check the roofing around it on the site visit.

Do we have to close the business for the install?

Not for long. The crane lift is the only step that needs the roof and the units off at once, and it fits in one day. We plan it for a day you're closed or a quiet morning, and the wiring and startup follow the next working day.

Does Mass Save's commercial rebate need approval before we sign?

It needs pre-approval before installation. Since July 1, 2026, every commercial heat pump project needs a commitment letter from Mass Save before the equipment goes in, and that letter is good for four months. We set the install date inside that window.

Can each apartment in our building have its own heat pump?

Yes, where each apartment has its own electric service. Each unit gets an outdoor unit and an air handler on that unit's meter, so each household runs its own thermostat and pays its own bill. The roof or rear yard has to hold the outdoor units with their clearances.

How do you price a commercial heat pump job?

From the site visit. Tonnage from the load calculation, the crane and roof work, the electrical service, controls and permits set the number, and the written estimate breaks each one out. Rebates come off after, once the pre-approval is in hand.

Related services

Get an estimate for commercial heat pumps

Tell us what heats it now and which rooms aren't working. We'll measure, lay out the system and the ducts, and put the plan and the price in writing.

Step 1 of 2

The house and the work