Boiler to heat pump conversion in Boston, MA

New ducts or small-duct high-velocity runs so a heat pump can heat and cool a radiator house.

Last Updated:

Small round high-velocity outlet in a plaster ceiling above a cast-iron radiator in an older Boston-area house
SizedFrom a room-by-room load calculation at your town's design temperature
MeasuredDuct static pressure and airflow before and after
TestedNitrogen pressure test and deep vacuum before the charge
In writingEquipment, duct work, electrical and permits listed line by line

Inside a Winter Hill boiler-to-heat-pump conversion

Basement trunk and branches for the first-floor flat, Winter Hill, Somerville
Basement trunk and branches for the first-floor flat
Round high-velocity outlet in a second-floor plaster ceiling, Winter Hill, Somerville
Round high-velocity outlet in a second-floor plaster ceiling

Two flats, two boilers, no ducts

A two-family on Winter Hill, built around 1905, with a 1,050-square-foot flat on each floor. Each flat has its own gas boiler in the basement feeding cast-iron radiators, and window units every summer. The owners want central cooling in both flats and both boilers gone, so the basement and yard work happens once.

Two floors, two duct answers

The first floor is straightforward: a trunk under the basement joists feeds seven floor registers and a hall return. The second floor sits under a low-slope roof with no attic, only a 14- to 20-inch cavity. Standard ducts won't fit there, so that flat gets small-duct high-velocity tubing instead.

The high-velocity side

A compact air handler goes in the rear hall closet. Fourteen 2-inch tubes run through the roof cavity to round ceiling outlets, each with a sound attenuator, and one return grille sits in the closet wall. The loads put each flat at 2 tons: 21,500 BTU an hour downstairs, 24,800 upstairs under the roof.

Boilers out, yard rules in

Once both systems are commissioned, a licensed gas fitter caps the boiler lines, 17 radiators are drained and carried out, and the floor holes are plugged. Somerville keeps HVAC out of the front yard, so both outdoor units stand in the rear yard on 18-inch stands. Each flat keeps its own meter, panel and thermostat.

Project facts
ServiceBoiler to heat pump conversion, two systems
WhereWinter Hill, Somerville
HouseAbout 1905 two-family, two flats of about 1,050 sq ft
BeforeTwo gas boilers, cast-iron radiators, window AC
After2-ton heat pump per flat: basement ducts below, high-velocity above
Price$38,900 before rebates
Time on siteEight working days

The radiators clank, every bedroom has a window unit in August, and there’s no obvious place for central air. Clement Boston Heat Pumps handles boiler to heat pump conversion in houses like this: we lay out new ducts or small-duct high-velocity runs, then put a cold-climate heat pump on them so the boiler can go.

New ducts make this a bigger job than a furnace swap. Our typical range for a heat pump with new ductwork or small-duct high-velocity is $20,000 to $40,000 and up, before rebates.

Why your radiators can’t connect to a ducted heat pump

Radiators heat a room with hot water or steam. A ducted heat pump heats air. Nothing joins the two, so a radiator house needs a way to move air into every room before a ducted system can take over from the boiler.

What about heat pumps that make hot water?

Air-to-water heat pumps feed radiators, but they work best at water temperatures well below what old cast iron was sized for, which can mean more or bigger radiators. They also don’t cool. We install ducted systems; our heat pump vs boiler guide weighs the two.

Finding room for ducts in an old house

Every layout starts from what the house already offers: an open basement under the first floor, an attic over the top floor, and closets that stack between floors. The first visit maps those, floor by floor, before anything gets priced.

  • Basement. A trunk along the main beam with short branches to floor registers under the windows heats the first floor without touching plaster.
  • Attic. An air handler on a platform feeds the top floor through ceiling registers. Those ducts get sealed and insulated, since the attic is cold in winter; see attic air handlers.
  • Stacked closets. A chase through closets on two floors carries a trunk to a middle floor that neither the basement nor the attic reaches.
  • Returns. The hard part. Every system needs air back to the air handler, usually through one central return per floor.

In a triple-decker or two-family, each unit normally gets its own system, thermostat and electric circuit, which keeps comfort and bills separate. More on routing in heat pumps in old houses.

When small-duct high-velocity fits better

When finished plaster and tight framing leave no room for 6-inch ducts. High-velocity systems push air through flexible tubes about 2 inches across, which fit inside wall cavities, between joists and through shallow roof spaces that standard ducts can’t pass.

Outlets are round and a few inches across, with several per room. Air leaves them fast and mixes the room well, so we place them in corners and along walls, out of the way of beds and chairs.

The trade-offs

High-velocity costs more per ton, and its blower works against higher pressure, so it uses more fan energy than a good conventional layout. We price it where conventional ducts won’t go, not as the default. The ductwork page covers both kinds.

What the first visit settles in a radiator house

Where the ducts can run comes first, then how much heat each floor loses. In a radiator house those two answers decide how many systems you need and whether any floor needs high-velocity tubing.

Sizing floor by floor

Top floors under a roof lose more heat than the floor below, and older houses often lose it through the attic and the top plates of the walls. We run the heat loss room by room and size each system to its floor, checking each unit’s output at 5°F against that floor’s coldest-night load.

Steam or hot water

It doesn’t change the duct plan, but it changes the removal. Steam systems carry larger pipes and heavier radiators; hot-water systems need draining and may have pipes in exterior walls. Both get capped below the floor. Either way, we size the heat pump from the heat loss, never from the old radiator count.

What happens to the boiler and radiators

For Mass Save’s whole-home rebate, the boiler has to be removed or disconnected. Radiators can come out for the floor space, or stay drained as furniture; the decision is yours, and it changes the restoration list.

  • The boiler comes out and a licensed gas fitter caps the gas line. An oil boiler adds the steps on our oil conversion page and a possible tank removal.
  • Radiators are drained, the supply and return pipes are capped below the floor, and the holes left in the floor are plugged.
  • A tankless coil or indirect tank on the boiler means your hot water needs a new source first, so we settle that before the removal date.
  • The chimney is abandoned, or kept for a water heater that still uses it.

What sets the price in a radiator house

Building air distribution from nothing is what pushes a boiler conversion above a furnace swap. The ducts, the openings and the number of systems move the number more than the equipment does.

  • Floors served, and whether the basement and attic routes exist
  • How much high-velocity tubing the plan needs
  • Openings in finished plaster, and what gets patched
  • One system or two, which also decides whether the panel needs work

Two systems can push an older service past its limit. Our typical range for an electrical service upgrade, usually 100 to 200 amps, is $3,000 to $6,500. The cost guide sets these beside the rebate amounts.

Rebates and local rules for boiler homes

Replacing a gas or oil boiler can qualify for Mass Save’s whole-home rebate when the heat pump carries the house and the boiler is removed or disconnected. Gas-heated homes apply through their gas company, oil homes through their electric company.

In light plant towns such as Belmont, oil and electric-heat switches go through the town utility’s program, while gas-heated homes can still use Mass Save. In Cambridge, a major renovation can’t install a new gas boiler, so a radiator house under renovation converts. In Somerville, outdoor units stay out of the front yard. The rebate guide has the current amounts.

What's included

Getting central heating and cooling into a house with radiators

New conventional ductsSmall-duct high-velocityBoiler stays, heat pump on one floor
Duct sizeTrunk plus 6- to 10-inch branchesCompact trunk plus 2-inch flexible tubesEither, for one floor
Where it fitsOpen basements and attics, stacked closetsFinished plaster, tight framing, shallow roof cavitiesTop floor or attic only
What you see in roomsRectangular floor or ceiling registersSmall round outlets, several per roomRegisters on one floor, radiators everywhere
Mass Save pathWhole-home if the boiler is removed or disconnectedWhole-home if the boiler is removed or disconnectedPartial-home with integrated controls, or basic
Our typical range$20,000 to $40,000 and up for new ductwork$20,000 to $40,000 and up for new ductworkPriced from the visit

Related resources

How a job runs

First call

You tell us what heats and cools the house now, which rooms aren't working, and roughly where the house is.

Home visit

We measure the house for a load calculation, test the ducts, check the panel and look for an outdoor spot.

Written estimate

Equipment, duct changes, electrical, permits and the rebate path, line by line, with our price.

Install

Permits first, then the work: usually two to five working days on site.

Commissioning

Pressure test, vacuum, charge by weight, airflow and controls set before we call it done.

Radiators now, central air next?

Tell us how many floors you have, what's above and below them, and how the house is heated. We'll walk the duct routes and price them.

Boiler to heat pump conversion: questions

Will a heat pump work with my existing radiators?

Not a ducted one. Cast-iron radiators need hot water or steam, and a ducted heat pump heats air. Air-to-water heat pumps exist for radiators; we install ducted systems, so a radiator house gets new air distribution and central cooling along with it.

How much plaster gets opened for new ducts?

An opening at each register or outlet, plus a few where runs turn between floors. High-velocity tubing snakes through wall and ceiling cavities, which keeps openings small. We mark every one on the plan before you sign anything.

Can I keep the boiler as backup?

Yes. It can stay on the radiators for the coldest days, or feed a hot-water coil in the new air handler. Either way Mass Save treats it as partial-home, and integrated controls decide when the heat pump hands off to the boiler.

Is a small-duct high-velocity system noisy?

Air leaves the outlets fast, so you hear a soft rush close to them. A sound attenuator on each run, enough outlets per room and placement in corners away from beds keep it down. The air handler sits in a closet or attic, not in a living space.

Does an oil boiler change the plan?

The ducts are the same job. An oil boiler adds the oil line cap, the tank decision and often the hot water, because many oil boilers make it too. Our oil conversion page covers those steps.

Related services

Get an estimate for boiler to heat pump conversion

Tell us what heats it now and which rooms aren't working. We'll measure, lay out the system and the ducts, and put the plan and the price in writing.