An attic air handler that heats and cools the upper floor, with short sealed ducts and a guarded drain.

Last Updated:

Horizontal heat pump air handler on a raised platform in a kneewall attic, with a secondary drain pan, insulated ducts and a service light
SizedFrom a room-by-room load calculation at your town's design temperature
MeasuredDuct static pressure and airflow before and after
TestedNitrogen pressure test and deep vacuum before the charge
In writingEquipment, duct work, electrical and permits listed line by line

A typical Wellesley attic heat pump

Horizontal air handler on its platform in the kneewall attic, Wellesley Hills
Horizontal air handler on its platform in the kneewall attic
New ceiling register in an upstairs bedroom, Wellesley Hills
New ceiling register in an upstairs bedroom

Upstairs that never feels right

A 1948 cape with a full rear dormer. An oil boiler heats both floors through baseboard, and two window units fight the July heat upstairs. Bedtime upstairs runs about 82°F in summer, and the front bedroom stays cold in January because its baseboard zone recovers slowly.

Why the kneewall attic

There's no duct path from the basement without opening two floors, and the owner wants to keep the hall closet. The rear kneewall attic, 22 feet long, puts every bedroom within 14 feet of a 2-ton horizontal air handler sized from a 21,500 BTU an hour upstairs load.

Protecting the ceilings

The unit sits on a platform over doubled joists with a secondary pan, float switches on both drains and a lit 30-inch service space. Six supply runs and one return are mastic-sealed, wrapped to R-8 and laid under the floor insulation. The line set climbs 38 feet in an exterior cover.

Backup and rebate

The upstairs baseboard zone stays on its own thermostat as backup, and the boiler keeps the first floor. Because the house heats with oil, the rebate comes from the Wellesley Municipal Light Plant's partial-home tier, about $2,250, rather than Mass Save, and the outdoor unit sits on an 18-inch stand.

Project facts
ServiceAttic air handler heat pump
WhereWellesley Hills
House1948 dormered cape, about 1,750 sq ft
BeforeOil boiler baseboard, window AC upstairs
After2-ton heat pump serving the second floor
Price$16,400 before rebates
Time on siteThree working days

Upstairs hits 82°F at bedtime in July, and the back bedroom is the coldest room in January, because the basement ducts never reached the second floor. A heat pump air handler in the attic can fix that floor without opening walls. Clement Boston Heat Pumps plans and installs attic systems for capes, colonials and dormered houses around Boston.

We price attic work from the access, the duct runs, the drainage and the electrical. The written estimate after the visit gives you one number with each part listed.

When the attic is the right place

When the upper floor needs its own heating and cooling and there’s no clean route for ducts from the basement. Capes and colonials with an attic AC, or no central air at all, fit this pattern.

Good candidates

  • A second floor cooled by an old attic AC that does nothing in winter.
  • A cape whose upstairs swings hot and cold on a boiler zone or electric baseboard.
  • A colonial whose basement furnace can’t push enough air up two floors.

Poor candidates

  • An attic reached only through a small scuttle, with no way to enlarge it.
  • Little headroom and no joists strong enough to carry a platform.
  • An upstairs closet near the middle of the floor you can give up, since a unit inside the heated space loses less.

What the attic costs you in heat

An attic sits outside the insulated part of the house. In July it can pass 120°F; in January it runs close to the outdoor temperature. Every foot of duct up there gives some of the heat pump’s output away.

We keep that loss small: short runs, joints sealed with mastic, ducts insulated to at least R-8, the cabinet sealed at its seams and the hatch weatherstripped. If an energy assessment is due, air sealing the attic floor first shrinks both the load and the losses.

Ducts buried in insulation

Ducts laid on the ceiling joists and covered by the attic floor insulation lose less than ducts left exposed. Ceiling registers fed from above stay short and direct, which suits bedrooms. Our old house guide covers the framing and plaster you’ll find on the way.

Keeping condensate out of the ceiling

In summer the attic coil makes water, sometimes gallons a day. If the drain clogs above a finished ceiling, that water comes through the drywall. Overflow protection is where an attic install earns its keep.

  • A trapped primary drain sloped at least 1/8 inch per foot to a drain point or condensate pump.
  • A float switch on the primary drain, so a clog shuts the unit down first.
  • A secondary pan under the whole cabinet, with its own float switch.
  • Drain lines kept away from eaves and gable vents where they could freeze.

In heating, the indoor coil is the warm side and makes no water. The winter water is the outdoor unit’s defrost melt, which is why it sits on a snow stand.

Getting the unit up there and keeping it serviceable

The air handler has to come through the hatch, sit level on solid framing and stay reachable for filter changes and repairs. That decides which unit fits.

Horizontal units suit low kneewall spaces; upright units suit taller attics. The mechanical code asks for an access opening large enough to remove the unit, a passageway no longer than 20 feet, a level 30-by-30-inch service space and a light at the unit.

Line set and power

The line set climbs from the outdoor unit inside an exterior cover or an interior chase. Long runs and tall lifts affect charge and oil return, so we stay inside the manufacturer’s limits. The air handler gets its own circuit and a service switch within sight of it.

What the first visit looks at upstairs

We start with the floor that’s uncomfortable, then go up into the attic with a flashlight and a tape measure.

  • A room-by-room load calculation for the upper floor, at your town’s design temperature.
  • Hatch size, headroom, joist size and the path a unit would take.
  • Insulation depth and the air leaks around the hatch, chimney and top plates.
  • Any old attic ducts, tested for leaks before we decide to keep them.
  • The line set route and room in the panel.

If the old attic AC ducts are sound, we test and seal rather than replace them. Our blog post on replacing attic central air covers timing the swap.

How an attic job runs

Most attic installs take two to four working days on site, depending on how many runs go in and how the line set reaches the attic. Attic work goes in the morning in summer, when the space is still bearable.

  1. Lay down floor protection on the stairs and hall, then build the platform and run a light to it.
  2. Cut the ceiling openings for registers and the return from below, with dust control.
  3. Set the air handler, the secondary pan and the ducts, sealing each joint as it goes in.
  4. Run the line set, the drain and the circuit, then test, evacuate and charge.
  5. Patch around the openings, then measure airflow at each register and set the controls.

Rebates: Mass Save or your light plant

An attic system that heats a floor previously heated by oil, propane, gas or electric baseboard can earn a rebate. Which program pays depends on who sells your electricity and what heats the house.

Your house Where the rebate comes from
Eversource or National Grid electric Mass Save partial-home or whole-home, per ton, for qualifying equipment installed by a participating contractor
Wellesley, oil or propane heat Wellesley Municipal Light Plant’s own program; partial-home pays $1,125 per ton up to $5,000
Wellesley, gas heat Mass Save, through the gas sponsor
Belmont, Braintree or another light plant town That utility’s program for oil, propane and electric heat; gas homes may still use Mass Save

Light plant towns also sit outside the seasonal heat pump electric rate. We confirm the program for your address in the estimate. Boiler homes adding an upstairs system can read baseboard heat to heat pump for the whole-house options.

What's included

Ways to heat and cool an upper floor

Attic air handlerAir handler in an upstairs closetRisers from the basement system
Opens wallsRarely: ceiling holes onlyOne closet given upA chase through both floors
Duct lossesKept small with sealing and insulationLowest, inside the heated spaceLowest, but often not enough air
Condensate riskOver a finished ceiling, so pans and switchesOver a floor, with a panIn the basement
Service accessThrough the attic hatchCloset doorBasement
How we price itAccess, ducts, drainage, electricalCloset framing and ductsChase work and duct changes

Related resources

How a job runs

First call

You tell us what heats and cools the house now, which rooms aren't working, and roughly where the house is.

Home visit

We measure the house for a load calculation, test the ducts, check the panel and look for an outdoor spot.

Written estimate

Equipment, duct changes, electrical, permits and the rebate path, line by line, with our price.

Install

Permits first, then the work: usually two to five working days on site.

Commissioning

Pressure test, vacuum, charge by weight, airflow and controls set before we call it done.

Upstairs too hot or too cold?

Tell us how the upper floor is heated now and how you get into the attic. We'll measure and send a written plan with our price.

Attic air handlers: questions

Is an attic a bad place for a heat pump air handler?

Not when it's done carefully. The attic is outside the insulated house, so ducts and the cabinet lose some heat and cooling there. Short runs, mastic-sealed joints, R-8 insulation and a sealed cabinet keep that loss small, and an upstairs closet is better still when you can spare one.

What stops an attic air handler from leaking through the ceiling?

A trapped and sloped primary drain, a float switch on that drain, and a secondary pan under the whole unit with its own float switch. If either switch sees water, it shuts the system off before the water reaches drywall. We test both switches at startup.

Can I reuse the ducts from my old attic AC?

Sometimes. Rigid or well-supported ducts that test tight and are insulated can stay. Old flex that is crushed, sagging or torn usually comes out, because a heat pump needs that air in winter too, not just in July. We test before we decide.

Does Wellesley use Mass Save for heat pump rebates?

Only for gas-heated homes. Wellesley's electricity comes from its municipal light plant, so homes heated by oil, propane or electric resistance apply to the Wellesley Municipal Light Plant program instead. Homes heated by natural gas apply to Mass Save through National Grid's gas side.

How do you price an attic heat pump install?

From the attic itself. Access and headroom, the platform, the number and length of duct runs, the drain route, the line set path and the electrical work drive the number. You get it as a written price after the home visit, with each part listed.